• Aten EA1340 enable you to get readings of Differential Pressure & Temperature. Environmental conditions can be monitored with alarms according to customizable minimum/maximum thresholds set for temperature and humidity. Some of the features include: high sensitivity and easy operation.
  • Aten EA1440 Photo Door sensor allows the monitoring of a rack mounted enclosure´s door access, notifying users when a door has been opened. Various conditions can be monitored with alarms according to customizable minimum/maximum settings. Some of the features include: easy operation and high sensitivity. Data Sheet
  • Aten EA1441 Inductive Proximity Door Sensor allows the monitoring of a rack mounted enclosure´s door access, notifying users when a door has been opened. Various conditions can be monitored with alarms according to customizable minimum/maximum settings. Some of the features include: high sensitivity and easy operation. Data Sheet
  • Aten PE1324G Energy PDU features  32A, 1 x IEC 60309 and 24 x IEC 13 power outlets.  It is 0U space saving design which allows it to be mounted vertically on the outside of a rack, resulting in a more efficient use of space in the server room. Dara Sheet Manual
  • The Aten EC2004 Energy Box features real-time status, system logs, threshold alerts, and event notifications. The EC2004 logs power and environmental conditions according to customizable minimum/maximum thresholds set for electrical current, voltage, temperature, humidity, and differential pressure. The EC2004 Energy Box allows power and environmental data to be monitored by display at the rack or remotely for easy viewing and maintenance. The Energy Box is a standalone unit with Over IP monitoring that is controlled by Web GUI or ATEN's eco Sensors software. Data Sheet Manual
  • The Aten NRGence PE5340SG 0U 40 AC outlets  is an intelligent PDUs that contains  in IEC configuration and provides secure, centralized, intelligent, power management of data center IT equipment (servers, storage systems, KVM switches, network devices, serial data devices, etc.), as well as the ability to monitor the center's health environment via sensors. It features 1 x IEC 60309 IEC 32A input x 40 x IEC320 C13 outlets. Data Sheet Manual
  • The Aten NRGence PE6324G 0U 24 AC Outlets eco Intelligent PDU provides the ability to monitor the center's health environment via sensors. NRGence eco PDU offers real-time power measurement – allowing you to monitor the power status of devices attached to the PDUs, either at the PDU device or Bank level, from practically any location via a TCP/IP connection. It also offers comprehensive power analysis reports – providing precise measurements of current, voltage, power and watt-hour in a real-time Display. It supports multiple power control methods – Wake on LAN, System After AC Back, Kill the Power and easy setup and operation via a browser-based user interface. The Pe6324G has 1 x IEC 60309,  21 x IEC 320 C13 and 3 x IEC 320 C19 outlets. Data Sheet  
  • The Aten PE7208G 1U eco PDUis an  intelligent PDU that contains  8 AC outlets and is available in various IEC socket configuration. They provide secure, centralized, intelligent, power management (power on, off, cycle) of data center IT equipment (servers, storage systems, KVM switches, network devices, serial data devices, etc.), as well as the ability to monitor the center's health environment via sensors. It supports outlet level power metering and monitoring and 2-level account/password security, IP/MAC filter, 128 bit SSL, RADIUS as well as current, voltage, power, power dissipation, temperature, and humidity metering and threshold level setting. Data Sheet  
  • Aten PE7208G eco PDU offers remote power control combined with real-time power measurement - allowing you to control and monitor the power status of devices attached to the PDU, either at the PDU device or outlet level, from practically any location via a TCP/IP connection. The PE7208G supports external temperature/temperature & humidity sensors for rack temperature and humidity monitoringCurrent, voltage, power, power dissipation, temperature, and humidity metering and threshold level setting. It features 1 x IEC 320 C20, 7 x C13 and 1 x C19. Data Sheet
  • The Aten NRGence PE7214 1U eco PDUs are intelligent PDUs that contain 14 AC outlets and are available in various IEC socket configurations, supports 2-level account/password security, IP/MAC filter, 128 bit SSL, RADIUS as well as PDU and outlet level power metering and monitoring. PE7214G also supports current, voltage, power, power dissipation, temperature, and humidity metering, threshold level setting and door sensor. Data Sheet Manual
  • Aten PE7328G NRGence 0U 28 Outlets Intelligent  eco PDU provide a secure, centralized, intelligent, power management (power on, off, cycle) of data center IT equipment (servers, storage systems, KVM switches, network devices, serial data devices, etc.), as well as the ability to monitor the center's health environment via sensors. The PDU offers remote power control combined with real-time power measurement — allowing you to control and monitor the power status of devices attached to the PDUs, either at the PDU device, bank, or outlet level, depending on the model, from practically any location via a TCP/IP connection. Input connection is 1 x IEC 60309 and outlet types are: 24 x IEC320 C13 + 4 x IEC320 C19 Bank1-1 : Outlet 1 – 14 ; 12 x C13 + 2 x C19 Bank1-2 : Outlet 15 – 22 ; 7 x C13 + 1 x C19 Data Sheet
  • The Aten NRGence PE8216G eco PDU is an intelligent PDU that contains 16 AC outlets and is available in various IEC socket configurations. Models in the advanced PE8 ranges feature NRGence´s proactive overload protection, which automatically powers off the last outlet that caused the current overload. It offers PDU and outlet level power metering and monitoring, current, voltage, power, power dissipation, temperature, and humidity metering and threshold level setting and supports door sensor. Input is 1 x IEC 60309 C20 and the outputs are: Total : 14 x IEC320 C13 + 2 x IEC320 C19 Bank1-1 : Outlet 1 – 8 ; 7 x C13 + 1 x C19 Bank1-2 : Outlet 9 – 16 ; 7 x C13 + 1 x C19 Data Sheet